HGT1

Print
Hochleistungsklappe
Description

DN 80 – DN 300

Triple offset valve as wafer type butterfly valve for high pressure and temperature loads

Wafer style

Technical Data
For installation between flanges EN 1092, PN 10/16/25/40, PS 25, ASME Cl 150/300, PS25

Temperature range
- 50 °C to + 450 °C
Vacuum: up to 1 mbar (abs)
FireSafe according to: DIN EN ISO 10497 and API 607

Face-to-face dimension
DIN EN 558 line 20
Optional: line 25 and line 16
API 609 table 1

Mounting flange
DIN EN ISO 5211

Test
DIN EN 12266 P10 P11 P12 F20

Marking
DIN EN 19, AD 2000

 

product information - series HGT (1.93 MB) Technical data sheets

...want a consultation?
We would be pleased to advise you on our products and services.